Twintex TFC-6110 10KVA AC Power Source ( 1 phase Input and 1 phase output)
$0.00
Product Tags:
Product Description:
The TFC61 series are single phase output AC power source, output capacity from 500VA to 800kVA. Adopting PWM high frequency technology & IGBT regulation mode, the TFC61 series features constant frequency and voltage with high accuracy. The output is galvanically isolated. The TFC61 series can be used to simulate grids of different countries, widely used in laboratories, production calibration & test and military applications.
Features:
★ Full range adjustable output: 1~300V, resolution 0.1V
★ Output frequency: 47-63Hz, 100Hz, 200Hz, 400Hz, optional 45-400Hz
★ Fast output key for 110/220V and 50/60Hz
★ Timing function, for output control 0~16 hours
★ High accuracy LED display for voltage, current, frequency, active power, power factor
★ Fast transient response, response time no more than 2ms for 100% load and unload
★ Multiple protections: OVP, OCP, OTP and OLP
★ Optional: RS-232/RS-485 interface for PC remote control on output frequency and voltage
★ Customized specifications and functions acceptable
Specifications:
Circuit mode |
IGBT/PWM |
Input |
1φ2W, 220V±10% or 3φ4W, 380V±10%, 50±5Hz |
Output |
|
Phase |
1 phase |
Low range |
1.0V-150.0V |
High range |
150.1V-300.0V |
Frequency |
47-63Hz, 100Hz, 200Hz, 400Hz, optional 45-400Hz Fast output key for 50/60Hz |
Voltage accuracy |
±1% (110Vor220V ±10%) ±1.5% (other range) |
Frequency stability |
≤0.1% |
Voltage stability |
±1% |
Harmonic distortion |
±2% (resistive load) |
Crest factor |
1.41±0.10 |
Line regulation |
≤1% |
Load regulation |
≤1% |
Efficiency |
≥80% (≥70% for models of 3kVA and below) |
Response time |
Max. 2ms |
Meter & Resolution |
|
Frequency meter |
4 digits LED, resolution 0.1Hz |
Voltmeter |
4 digits LED, resolution 0.1V |
Ammeter |
4 digits LED, resolution 0.001A/0.1A |
Power meter |
4 digits LED, resolution 0.01W/0.1kW |
Power factor meter |
3 digits LED, resolution 0.01 |
Preset function |
Preset output voltage, output frequency and output voltage floating ratio |
Fast key function |
Fast key for output voltage switch, frequency switch, output voltage floating selection |
Alarm function |
Audible and visual alarm once protective device activated; display error code on LED |
Protection |
Fuse switch for input and output; Fast-response circuit to detect over voltage, over current, over load, over temperature and short circuit; Output will be shut down in protection mode. |
Cooling |
Cooling fan |
Cabinet protection grade |
IP2X |
Chassis structure |
Bench type (500VA, 1kVA) or cabinet type |
Operation environment |
0℃-40℃, ≤90% RH(Non-condensing), Altitude: 1500 feet |
Output specifications (1 phase input)
Model |
61005 |
6101 |
6102 |
6103 |
6105 |
6106 |
6110 |
6115 |
|
Output capacity |
500VA |
1KVA |
2KVA |
3KVA |
5KVA |
6KVA |
10KVA |
10KVA |
|
Max. current |
1.0V-150.0V |
4.6A |
9A |
18A |
27A |
45A |
54A |
90A |
136A |
150.1V-300.0V |
2.3A |
4.5A |
9A |
13.5A |
22.5A |
27A |
45A |
68A |
Output specifications (3 phase input)
Model |
6110 |
6115 |
6120 |
6130 |
6145 |
6160 |
61100 |
61150 |
|
Output capacity |
10kVA |
15kVA |
20kVA |
30kVA |
45kVA |
60kVA |
100kVA |
150kVA |
|
Max. current |
1.0V-150.0V |
90A |
136A |
180A |
270A |
900A |
540A |
900A |
1360A |
150.1V-300.0V |
45A |
68A |
90A |
135A |
450A |
2700A |
450A |
680A |