Features
  • Operating voltage (DC):1.5V~150V
  • Operating Mode : C.C / C.V / C.R / C.P / CC+CV / CR+CV / CP+CV
  • Parallel Connection of Inputs for Higher Capacity (Max : 9,450W)
  • Support of High Slew Rate:Max 16A/us
  • Run Program Function(GO/NO GO Test)
  • Sequence Function for High Efficient Load Simulations
  • Commands are compatible with Kikusui PLZ-4W model.
  • Dynamic(Switching) Function:0.0166Hz ~20kHz
  • Soft Start Function:Off / On(1~200ms, Res:1ms)
  • Adjustable OCP / OVP / OPP / UVP Setting
  • Short Circuit Function
  • Timer function : Elapsed Time of load on
  • Cut Off Time(Auto Load Off Timer ):1s to 999h 59min 59s or Off
  • External Channel Control / Monitoring via Analog Control Connector
  • Setup Memories:100 sets
  • 3.5 Inch TFT LCD Display
  • Multi Interface : USB 2.0 Device / Host , RS-232 , GPIB (Optional)

The PEL-3000 series, a single-channel, programmable D.C. electronic load with 0.01mA current resolution and 16A/μs current Slew Rate, is very ideal for testing server power supply and SPS (Switching Power Supply) for commercial and industrial computers. For a heavy-duty device like cloud ecosystem running 24-hour nonstop operations, a stable and high-power power supply, ranging from 350W to 1500W, is required to maintain the normal operation of server, Hub, and the equipment of data storage and internet communications. Owing to the increasing demand of data transmission and large scale data storage of telecommunications systems, the infrastructure of internet communications is in the pace of rapid expansion. This has greatly boosted the market demand of telecommunications equipment powered by power supply of 2000W and above. The flexible power combination of PEL-3000 meets the test requirements of present high-power power supply.


Model Item Voltage / Current / Power
PEL-3021 DC Electronic Load  0 - 35A / 1.5 - 150V , 175W
PEL-3041 DC Electronic Load  0 - 70A / 1.5 - 150V , 350W
PEL-3111 DC Electronic Load  0 - 210A / 1.5 - 150V , 1050W
PEL-3211  Booster 0 - 420A / 1.5 - 150V , 2100W
PEL-3212 DC Electronic Load  0 - 420A / 1.5 - 150V , 2100W
PEL-3323 DC Electronic Load 0 - 630A / 1.5 - 150V , 3150W
PEL-3424 DC Electronic Load 0 - 840A / 1.5 - 150V , 4200W
PEL-3535 DC Electronic Load 0 - 1050A / 1.5 - 150V , 5250W
PEL-3322 DC Electronic Load 0 - 630A / 1.5 - 150V , 3150W
PEL-3533 DC Electronic Load 0 - 1050A / 1.5 - 150V , 5250W
PEL-3744 DC Electronic Load 0 - 1470A / 1.5 - 150V , 7350W
PEL-3955 DC Electronic Load 0 - 1890A / 1.5 - 150V , 9450W

 

PEL-3021 / PEL-3041 / PEL-3111 / PEL-3211
 
 

Model PEL-3021 PEL-3041 PEL-3111 PEL-3211
Voltage 1.5V~150V 1.5V~150V 1.5V~150V 1.5V~150V
Current 35A 70A 210A 420A
Power 175W 350W 1050W 2100W
Constant Current Mode
Operating Range 0~35A 0~3.5A 0~0.35A 0~70A 0~7A 0~0.7A 0~210A 0~21A 0~2.1A 420A
Accuracy of Setting H,M,L ±(0.2 % of set + 0.1 % of f.s*1) + Vin*2/500 kΩ ±(1.2% of set +1.1% of f.s)
Accuracy of Setting(Parallel) H,M,L ±(1.2 % of set + 1.1 % of f.s*3)   
Resolution 1mA 0.1mA 0.01mA 2mA 0.2mA 0.02mA 10mA 1mA 0.1mA N/A
Constant Resistance Mode
Operating Range H 23.33365S~400uS
(42.857mΩ~2.5kΩ)
46.6672S~800uS
(21.428mΩ~1.25KΩ)
140.0016S~2.4mS
(7.1427mΩ~416.6667Ω)
28.0002s~484.8us
(35.7135mΩ~2.08334Ω)
M 2.33336S~40uS
(428.566mΩ~25kΩ)
4.6667S~80uS
(214.28mΩ~12.5kΩ)
14.0001S~242.4uS
(71.427mΩ~4.16667Ω)
L 0.233336S~4uS
(4.28566Ω~250kΩ)
0.46667S~8uS
(2.1428Ω~125kΩ)
1.40001S~24.24uS
(714.27mΩ~41.6667kΩ)
Accuracy of Setting H,M,L  ±(0.5 % of set*4 + 0.5 % of f.s*1) + Vin*3/500kΩ ±(1.2% of set +1.1% of f.s)
Resolution 400uS 40uS 4uS 800uS 80uS 8uS 2.4mS 240uS 24uS N/A
Constant Voltage Mode
Operating Range H 1.5V~150V 1.5V~150V 1.5V~150V 1.5V~150V
L 1.5V~15V 1.5V~15V 1.5V~15V 1.5V~15V
Accuracy of Setting H,L ±(0.1 % of set + 0.1 % of f.s.) ±(0.1 % of set + 0.1 % of f.s.) ±(0.1 % of set + 0.1 % of f.s.) N/A
Resolution H,L 10mV / 1mV 10mV / 1mV 10mV / 1mV N/A
Constant Power Mode
Operating Range H 17.5W~175W 35W~350W 105W~1050W 210W~2100W
M 1.75W~17.5W 3.5W~35W 10.5W~105W 21W~210W
L 0.175W~1.75W 0.35W~3.5W 1.05W~10.5W 2.1W~21W
Accuracy of Setting H,M,L ±(0.6 % of set*5  + 1.4 % of f.s*6) N/A
Resolution 10mW 1mW 0.1mW 10mW 1mW 0.1mW 100mW 10mW 1mW N/A
PARALLEL Mode
Capacity 875W 1750W 5250W PEL-3111 with 4 booster
units: Max 9.45kW
Slew Rate
Setting Range
(CC mode)
H 2.5mA/us~2.5A/us 5mA/us~5A/us 16mA/us~16A/us 16mA/us~16A/us
M 250uA/us~250mA/us 500uA/us~500mA/us 1.6mA/us~1.6A/us 1.6mA/us~1.6A/us
L 25uA/us~25mA/us 50uA/us~50mA/us 160uA/us~160mA/us N/A
Resolution   0.1uA ~ 1mA 0.2uA ~ 2mA 0.6uA ~ 6mA N/A
Setting Range
(CR mode)
H 250uA/us~250mA/us 500uA/us~500mA/us 1.6mA/us~1.6A/us 1.6mA/us~1.6A/us
M 25uA/us~25mA/us 50uA/us~50mA/us 160uA/us~160mA/us 160uA/us~160mA/us
L 2.5uA/us~2.5mA/us 5uA/us~5mA/us 16uA/us~16mA/us N/A
Resolution   0.1uA ~ 1mA 0.2uA ~ 2mA 0.6uA ~ 6mA N/A
Accuracy of Setting H,M,L ±(10 % of set*7+ 5us) N/A
METER
Voltmeter   Accuracy ±(0.1 % of rdg + 0.1 % of f.s.) N/A
Ammeter Accuracy ±(0.2 % of rdg + 0.3 % of f.s.) N/A
Ammeter
(Parallel Operation)
Accuracy ±(1.2 % of rdg + 1.1 % of f.s.) N/A
DYNAMIC MODE
Operation mode  CC / CR 
T1 & T2  0.025ms ~ 10ms / Res : 1us  ; 1ms ~ 30s / Res : 1ms
Accuracy  1us / 1ms ±100ppm               
Slew Rate
(CC Mode)
H 2.5mA/us~2.5A/us 5mA/us~5A/us 16mA/us~16A/us 16mA/us~16A/us
M 250uA/us~250mA/us 500uA/us~500mA/us 1.6mA/us~1.6A/us 1.6mA/us~1.6A/us
L 25uA/us~25mA/us 50uA/us~50mA/us 160uA/us~160mA/us N/A
Slew Rate
(CR Mode)
H N/A 
M
L
Current Accuracy  ±0.4%F.S  ±0.4%F.S  ±0.4%F.S  ±(1.2% of set +1.1% of f.s)
Protection Function
Overvoltage (OVP)  Adjustable ; Turns off the load at 110% of the rated voltage N/A
Overcurrent (OCP)  0.03A ~ 38.5A (Adjustable) 0.06A ~ 77A (Adjustable) 0.2A ~ 231A (Adjustable)
Overpower (OPP)  0.1W ~ 192.5W  (Adjustable) 0.3W ~ 385W (Adjustable) 1W ~ 1155W (Adjustable)
Overheat (OHP)  Turns off the load when the heat  sink temperature reaches 95 °C
Undervoltage (UVP)   Adjustable : Turns off the load when detected.   Can be set in the range of 0 V to 150 V or Off.
Reverse connection (REV)  By diode. Turns off the load when an alarm occurs.
General Specifications
Power Source  AC100V ~ 230V±10% ; 50Hz / 60Hz ± 2Hz
Interface  USB/RS232C/Analog Control (Standard) ; GPIB(Option)
Weight   Approx. 6kg 7kg 17kg 23kg
DIMENSIONS & WEIGHT  214.5(W)x124(H)x400(D)mm.  214.5(W)x124(H)x400(D)mm 429.5(W)x128(H)x400(D)mm 427.7(W)x128(H)x592.5(D)mm
 
Sold Out
Product Images (click to enlarge)
  • GW PEL 3021 Single channel programmable DC electronic load
  • GW PEL 3021 Single channel programmable DC electronic load
  • GW PEL 3021 Single channel programmable DC electronic load
  • GW PEL 3021 Single channel programmable DC electronic load
  • GW PEL 3021 Single channel programmable DC electronic load