Features

  • Rugged IP68 housing withstands 1.5 meter drop test
  • Wireless measurement of pressure, air velocity, air flow, temperature, and humidity

 

 

Product Applications

  • Building commissioning
  • Building balancing
  • Testing HVAC equipment performance

 

Specifications

UHH2 SPECIFICATIONS
Display: 4.3" QHD Gorilla glass, 960x540.
Wireless Distance: 50' (15 m) or greater.
Response Time: 1 s.
Temperature Limits: Operating: -4 to 140°F (-20 to 60°C); Storage: -40 to 176°F (-40 to 80°C).
Humidity Limits: 5 to 95% RH.
Power Requirements: 2000mAh lithium ion battery, installed functional, non-replaceable.
Memory: RAM 1G & ROM 4G.
Operating System: Android® 4.2.2.
CPU: MTK6589W Quad Core 1.2 GHz.
Enclosure Rating: IP68.
Weight: 15.9 oz (450 g).
Agency Approvals: CE.
AP2 THERMO-ANEMOMETER PROBE SPECIFICATIONS
Service: Dry, clean air.
Temperature Limits: Process: -20 to 200°F (-29 to 93°C); Ambient: -20 to 140°F (-29 to 60°C); Battery Charging: 32 to 113°F (0 to 45°C).
Range: Air Velocity: 0 to 6000 FPM (0 to 30 m/s); Volumetric Air: 999,999 in selected flow units; Temperature: -40 to 212°F (-40 to 100°C).
Accuracy: Air Velocity: ±3% FS within temperature range of 40 to 90°F (4 to 32°C); Temperature: ±0.5°F (±0.28°C).
Response Time: 1 s.
Probe Length: 8" (203 mm) insertion.
Power Requirements: 3.7 V YT562447 Lithium ion battery, installed functional, user replaceable.
Maximum Wireless Distance: 50' (15 m).
Handle Enclosure: Thermoplastic elastomer over polycarbonate.
Supplied With: Wrist strap.
Weight: 11.2 oz (331.22 g).
Agency Approvals: CE (not while charging), FCC compliant.
RP2 THERMO-HYGROMETER PROBE SPECIFICATIONS
Service: Clean air.
Temperature Limits: Process: -4 to 140°F (-20 to 60°C); Ambient: 5 to 125°F (-15 to 51°C); Battery Charging: 32 to 113°F (0 to 45°C).
Range: RH: 0 to 100% (non-condensing); Temperature: -22 to 140°F (-30 to 60°C).
Accuracy: RH: ±2% @ 25°C (10 to 90% RH); ±4% (0 to 10, 90 to 100% RH); Temperature: ±0.54°F @ 77°F (±0.3°C @ 25°C).
Response Time: 1.5 s.
Probe Length: 8" (203 mm) insertion.
Power Requirements: 3.7 V YT562447 Lithium ion battery, installed functional, user replaceable.
Maximum Wireless Distance: 50' (15 m).
Handle Enclosure: Thermoplastic elastomer over polycarbonate.
Supplied With: Wrist strap.
Weight: 11.2 oz (331.22 g).
Agency Approvals: CE (not while charging), RoHS, FCC compliant.
VP2 VANE THERMO-ANEMOMETER PROBE SPECIFICATIONS
Service: Clean air.
Temperature Limits: Process: -4 to 140°F (-20 to 60°C); Ambient: 5 to 125°F (-15 to 51°C).
Range: Air Velocity: 50 to 5000 fpm (0.25 to 25 m/s); Temperature: -22 to 140°F (-30 to 60°C); Relative Humidity: 0 to 100% RH; Air Volume: 999,999 in selected units.
Accuracy: Air Velocity: 0.25 to 10 m/s: ±1.5% of reading ±20 fpm (±0.1 m/s); 10 to 20 m/s: 1.5% of reading ±40 fpm (±0.2 m/s); 20 to 25 m/s: ±1.5% of reading ±60 fpm (±0.3 m/s); Temperature: ±0.54°F @ 77°F (±0.3°C @ 25°C); Relative Humidity: ±2% @ 77°F (25°C) (10 to 90% RH); ±4% (0 to 10% and 90 to 100%).
Response Time: Air Velocity: 1 s; Temperature: 1.5 s; Relative Humidity: 1.5 s; Air Volume: 1 s.
Probe Length: 8" (203 mm) insertion.
Power Requirements: 3.7 V YT562447 Lithium ion battery, installed functional, user replaceable.
Battery Charging Limits: 32 to 113°F (0 to 45°C).
Maximum Wireless Distance: 50' (15 m).
Vane Material: Anondized aluminum.
Handle Enclosure: Thermoplastic elastomer over polycarbonate.
Supplied With: Wrist strap.
Weight: 13.6 oz (402.20 g).
Agency Approvals: CE (not while charging), RoHS, FCC compliant.
WDPM SPECIFICATIONS
Service: Non-corrosive dry gases.
Wetted Materials: Consult factory.
Accuracy: ±0.5% FS span @ 25°C (includes non linearity, hysteresis, and non repeatability).
Pressure Limits: See model chart on catalog page.
Engineering Units: Pressure: in w.c., ft w.c., in Hg, psi, OzSl, mm w.c., cm w.c., mBar, Pa, hPa, and kPa; Velocity: fpm, mph, kn, m/s, m/h, k/h, and fps; Flow: cfm, gpm, gph, gpd, m3/s, m3/h, lps, lpm, and lph.
Temperature Limits: Compensated: 32 to 140°F (0 to 60°C); Process/Ambient: 14 to 140°F (-10 to 60°C).
Thermal Effects: ±0.01% FS/°F (±0.02% FS/°C).
Battery Charging Limits: 32 to 113°F (0 to 45°C).
Power Requirements: 3.7 V YT562447 lithium ion battery, installed functionally, user replaceable.
Wireless Distance: At least 50' (15 m).
Connections: Two barbed connections for use with 1/8" (3.18 mm) or 3/16" (4.76 mm) ID tubing.
Weight: 2.5 oz (70.87 g).
Agency Approvals: CE with CE approved charger, RoHS, FCC.